Welcome to the Hayward Super Pump 700 manual. This guide provides essential information for installing, operating, and maintaining your pump, ensuring optimal performance and longevity.
Safety Instructions
Always follow safety guidelines to prevent injury. Identify and understand safety symbols like DANGER, WARNING, and NOTICE. Only qualified personnel should perform installations and repairs. Use genuine Hayward replacement parts for optimal performance and warranty validity.
2.1 General Precautions
Always follow basic safety precautions to ensure safe operation. Inspect the pump and surrounding area before use. Ensure all electrical connections comply with local codes and NEC regulations. Never operate the pump near open flames or sparks. Keep children and pets away from the pump and pool area. Avoid exposing the pump to extreme temperatures or direct sunlight. Use only genuine Hayward replacement parts to maintain safety and performance. Properly vent the area to avoid gas buildup. Follow all instructions carefully to prevent accidents and ensure longevity of the pump. Regular maintenance is crucial for optimal function and safety.
2.2 Specific Warnings
Never use the pump at pressures exceeding 5 PSI when purging air. Avoid using water to clean the motor, as it may damage components. Ensure all suction and discharge valves are open during operation to prevent damage. Failure to prime the pump within five minutes indicates a potential issue requiring immediate attention. Do not ignore unusual noises, as they may signal wear or damage. Always turn off the power before servicing. Use only low-pressure blowers for air purging to avoid system damage. Improper handling of replacement parts can lead to scratches or improper sealing, compromising pump efficiency and safety.
2.3 Understanding Safety Symbols
The safety-alert symbol appears throughout this manual to alert you to potential hazards. When you see this symbol, carefully review the accompanying text. The symbol may be paired with WARNING, CAUTION, or NOTICE. WARNING indicates hazards that could cause serious injury, death, or property damage. CAUTION alerts you to minor or moderate hazards that could result in injury or damage. NOTICE provides important information unrelated to safety but critical for proper operation. Always heed these warnings to ensure safe and effective use of your Hayward Super Pump 700. Failure to do so may void your warranty or result in severe consequences.
Installation
Ensure the electrical supply matches the motor’s voltage and phase. Hire a licensed electrician for wiring, following local codes and NEC regulations. Properly prepare the site and connections.
3.1 Preparing the Site
Before installing the Hayward Super Pump 700, ensure the site is level, firm, and well-drained. Choose a location with adequate ventilation to avoid moisture buildup. Clear the area of debris and obstructions to facilitate smooth installation. Ensure the pump is positioned away from direct sunlight and heat sources to maintain efficiency. Verify that the surrounding area complies with local building codes and safety standards. Proper site preparation ensures stable operation and prolongs the pump’s lifespan. Follow all safety guidelines and manufacturer recommendations for a secure setup.
3.2 Electrical Wiring
Ensure all electrical wiring for the Hayward Super Pump 700 is performed by a licensed electrician, adhering to local codes and NEC regulations. Verify the motor’s voltage, phase, and cycle match the electrical supply. Use appropriately sized wire based on the pump’s horsepower rating and distance from the power source. Avoid using extension cords or damaged wiring. Ground the system properly to prevent electrical hazards. Do not operate the pump near water or in wet conditions. Follow the manufacturer’s guidelines for safe and reliable electrical connections to ensure optimal performance and compliance with safety standards. Always refer to the manual for specific wiring instructions.
3.3 Plumbing Connections
Ensure proper plumbing connections for the Hayward Super Pump 700 by using the correct size and type of plumbing material. Install unions on both suction and discharge sides for easy maintenance and disassembly. Check all connections for leaks before starting the pump. Properly prime the pump by ensuring the strainer basket is filled with water and all air is purged from the system. Secure the strainer cover tightly to avoid any air leaks. Follow the manufacturer’s recommendations for plumbing configuration to ensure efficient operation. If unsure, consult a professional to avoid installation errors and potential damage to the pump. Always refer to the manual for detailed plumbing guidelines.
3.4 Priming the Pump
Priming the Hayward Super Pump 700 ensures efficient operation and prevents damage. Begin by ensuring the pump basket is filled with water. Open the suction and discharge valves fully. Turn on the pump and allow it to run for 5 minutes to purge air from the system. If the pump does not prime within this time, check for blockages in the suction line or closed valves. Repeat the process until the pump operates smoothly without air leaks. Proper priming prevents motor overheating and ensures optimal performance. Always follow the manual’s specific priming instructions for your pump model.
3.5 Initial Startup
After installation and priming, proceed with the initial startup of the Hayward Super Pump 700. Ensure all electrical connections are secure and match the motor’s voltage rating. Turn on the power and allow the pump to run for 5-10 minutes to verify smooth operation. Check for leaks at connections and around the shaft seal. Monitor the pump’s performance, ensuring it reaches the desired flow rate without unusual noise or vibration. If issues arise, refer to the troubleshooting guide. Proper startup ensures optimal performance and extends the pump’s lifespan. Always follow the manual’s specific startup instructions for your model.
Operation
Proper operation of the Hayward Super Pump 700 involves daily use and seasonal shutdown procedures. Follow guidelines for safe and efficient operation to maintain performance and longevity.
4.1 Daily Use
For optimal performance, ensure the electrical supply matches the motor’s voltage and phase. Always keep the suction and discharge valves open during operation. Monitor the pump’s operation to ensure it primes within five minutes; if it doesn’t, stop the motor and check for obstructions. Regularly inspect the strainer basket and clean it as needed to maintain proper flow. Avoid using excessive force when opening or closing valves to prevent damage. Use only genuine Hayward replacement parts to ensure reliability and safety. Refer to the troubleshooting guide for common issues and solutions to maintain efficiency and longevity of your Hayward Super Pump 700.
4.2 Seasonal Shutdown
For seasonal shutdown, ensure the pump is properly winterized to prevent damage from freezing temperatures. Drain all water from the pump and plumbing lines, and disconnect the electrical power supply. Clean the strainer basket and store it in a dry place. Apply a winterizing kit if recommended. Cover the pump to protect it from debris and frost. Store the pump in a cool, dry location to maintain its condition. Before restarting in the next season, inspect for any signs of damage or wear and ensure all connections are secure. Proper winterization ensures the pump remains in optimal condition for the next use.
Maintenance
Regular maintenance is crucial for optimal performance. Clean the strainer basket weekly, check for wear, and replace genuine Hayward parts as needed. Inspect seals annually for leaks.
5.1 Routine Maintenance
Perform routine maintenance to ensure your Hayward Super Pump 700 operates efficiently. Clean the strainer basket weekly and inspect it for damage or debris buildup. Check the pump housing and seals for leaks and wear. Regularly lubricate moving parts and ensure all connections are secure. Refer to the troubleshooting guide if issues arise. Always use genuine Hayward replacement parts to maintain warranty and performance. Schedule annual professional inspections to prevent major repairs. Proper maintenance extends the pump’s lifespan and ensures reliable pool operation.
5.2 Storage/Winterization
Proper storage and winterization of your Hayward Super Pump 700 are crucial to prevent damage and ensure longevity. Drain the pump and plumbing lines thoroughly, especially in freezing temperatures. Use a low-pressure blower to purge air from the system, but avoid high-pressure blowers that could damage components. Apply a rust inhibitor to internal parts and store the pump in a dry, protected area. Ensure the strainer basket is clean and dry before storage. For extended periods, consult the manual for detailed winterization steps to safeguard against corrosion and freezing. Always follow manufacturer guidelines to prepare your pump for seasonal shutdown.
Troubleshooting
Identify and resolve common issues with your Hayward Super Pump 700 using this guide. Address problems like priming failures or noise, and ensure optimal performance with genuine parts.
6.1 Common Issues
Common issues with the Hayward Super Pump 700 include priming failures, excessive noise, and reduced flow rates. These problems often stem from air leaks, clogged filters, or worn-out seals. Motor overheating and bearing noise may indicate improper installation or chemical imbalances. Regular maintenance, such as cleaning the strainer and replacing worn parts, can prevent many of these issues. Always use genuine Hayward replacement parts to ensure compatibility and longevity. If problems persist, consult the troubleshooting guide or contact a certified technician for assistance.
6.2 Troubleshooting Guide
For the Hayward Super Pump 700, common issues can often be resolved with simple troubleshooting steps. If the pump fails to prime, check for air leaks in the suction line or ensure all valves are open. Excessive noise may indicate worn bearings or debris in the strainer basket. Low flow rates could result from clogged filters or obstructed pipes. Always inspect and clean the strainer basket regularly. If the motor overheats, ensure proper ventilation and verify that the electrical supply matches the motor’s requirements. For persistent issues, refer to the troubleshooting chart in the manual or contact Hayward support.
Replacement Parts
Use only Hayward Genuine Replacement Parts for the Super Pump 700. This ensures optimal performance and maintains your warranty. Visit authorized dealers for authentic components like SPX2600G1.
7.1 Genuine Hayward Parts
Using Hayward Genuine Parts ensures your Super Pump 700 operates at peak performance and maintains its warranty. These parts are precision-engineered to meet strict quality standards. Always opt for components like the SPX2600G1 mounting foot or SPX0125F motor assembly for reliability. Genuine Hayward parts include essential items such as seals, motors, and housing components, ensuring compatibility and durability. Avoid non-genuine parts, as they may void your warranty and compromise performance. Purchase from authorized Hayward dealers to guarantee authenticity and support. By choosing Genuine Hayward Parts, you extend the life of your pump and maintain its efficiency season after season.
7.2 Where to Buy
For authentic Hayward Super Pump 700 parts, purchase from authorized Hayward dealers or visit the official Hayward website. Local pool supply stores and online retailers like Amazon also carry genuine parts. Ensure the seller is verified to avoid counterfeit products. Always check for the Hayward logo and part numbers to confirm authenticity. Buying from authorized sources guarantees warranty coverage and ensures compatibility with your pump. For convenience, use the dealer locator tool on the Hayward website to find a trusted supplier near you.
Warranty Information
The Hayward Super Pump 700 is backed by a limited warranty covering defects in materials and workmanship. The warranty period varies by component, typically one year from the date of purchase. It includes parts and labor for repairs due to manufacturing defects. However, damage caused by misuse, improper installation, or the use of non-genuine parts is not covered. Consequential damages are excluded from warranty claims. To maintain warranty validity, ensure all installations and maintenance follow the instructions in this manual. Register your product online through the Hayward website to activate your warranty and receive updates on coverage.
Product Registration
Registering your Hayward Super Pump 700 is essential to activate your warranty and receive important product updates. Visit the Hayward website at www.hayward.com to complete the registration process. You will need your product’s serial number, model number, and purchase date. Registration ensures you receive notifications about software updates, maintenance reminders, and exclusive customer support resources. This process is quick and ensures you stay connected for any assistance or new features. By registering, you also gain access to Hayward’s online support tools and troubleshooting guides. Registration is a simple step to maximize your product experience and warranty benefits.
Hayward Super Pump 700 vs Other Models
The Hayward Super Pump 700 stands out for its advanced features and reliability compared to other models. Its high-efficiency motor and durable construction make it a top choice for in-ground pools. Unlike older models like the Super II, the 700 Series offers improved flow rates and head pressure, ensuring better performance. It also features a corrosion-resistant design, making it more long-lasting than competitors. The 700 Series is ideal for larger pools or complex systems, while other models may suffice for smaller setups. Its advanced Teflon-encapsulated motor ensures quieter operation and higher efficiency, making it a superior option for modern pool needs.
Environmental Benefits
The Hayward Super Pump 700 is designed with eco-friendly features to minimize its environmental impact. Its high-efficiency motor reduces energy consumption, lowering your carbon footprint. By using less power, it contributes to energy conservation and helps reduce greenhouse gas emissions. The pump’s durable construction also reduces the need for frequent replacements, minimizing waste. Additionally, its advanced design ensures quiet operation, preserving the natural tranquility of your surroundings. With its energy-saving capabilities and long-lasting performance, the Super Pump 700 supports sustainable pool ownership while maintaining superior functionality.
Notes on Using Non-Genuine Parts
Using non-genuine parts for your Hayward Super Pump 700 can lead to compatibility issues, reduced performance, and increased risk of damage. Genuine Hayward parts are specifically designed to ensure optimal functionality and longevity of your pump. Non-genuine parts may void your warranty and could result in safety hazards, such as electrical or mechanical failures. Always prioritize using authentic Hayward components to maintain the integrity and efficiency of your pump. For more information, refer to the replacement parts section or contact Hayward customer support.
Hayward’s Commitment to Quality
Hayward has built a reputation for delivering high-quality pool equipment, and the Super Pump 700 is no exception. Engineered with precision, this pump is designed to provide durability and reliability for years of trouble-free operation. Hayward’s commitment to quality ensures that every component meets rigorous standards, from the heavy-duty construction to the advanced Tefc motor. The company’s focus on innovation and customer satisfaction drives the production of pumps that withstand harsh pool environments while maintaining superior performance. By adhering to international safety and quality standards, Hayward guarantees a product that is both efficient and long-lasting, backed by comprehensive warranties and dedicated customer support.
User Testimonials
Users consistently praise the Hayward Super Pump 700 for its reliability and performance. Many highlight its ease of installation and quiet operation, making it a top choice for pool owners. One user noted, “This pump has been a workhorse for my pool, running smoothly season after season.” Another added, “The installation was straightforward, and it’s been trouble-free ever since.” Pool professionals also commend its durability, stating, “It’s a testament to Hayward’s commitment to quality.” Overall, the Super Pump 700 has earned a reputation for being efficient, long-lasting, and user-friendly, making it a favorite among homeowners and professionals alike.
Technical Specifications
The Hayward Super Pump 700 offers robust performance with a 1.65 THP motor, suitable for demanding pool requirements. It operates at 230/115V, single-phase, ensuring versatility. The pump delivers a maximum flow rate of 70 GPM and a total dynamic head of 100 feet. Featuring a durable TEFC motor and chemical-resistant Viton seal, it ensures long-lasting reliability. Compact dimensions (24″ L x 11″ W x 13″ H) and a weight of 52 pounds make installation straightforward. Designed for efficiency and durability, the Super Pump 700 is a reliable choice for pool owners seeking consistent performance and hassle-free operation.
Compliance and Certifications
The Hayward Super Pump 700 is designed to meet rigorous industry standards, ensuring safety and performance. It is UL (Underwriters Laboratories) and CSA (Canadian Standards Association) certified, adhering to strict safety requirements for pool equipment. The pump complies with local electrical codes and NEC regulations, guaranteeing reliable operation. Note that 50Hz models are not UL or CSA listed; By using only genuine Hayward parts, you maintain compliance with these certifications, ensuring optimal safety and efficiency. This pump is engineered for use in in-ground swimming pools and spas, providing a durable and environmentally friendly solution for pool circulation needs.
Accessories
The Hayward Super Pump 700 can be enhanced with a range of genuine accessories to ensure optimal performance and longevity. Key accessories include replacement shaft seal kits (e.g., SPX2600G1) and strainer baskets (e.g., SPX1600Z4), designed to maintain proper flow and efficiency. Additionally, unions and couplers are available for secure connections. Always use genuine Hayward parts to ensure compatibility and maintain warranty coverage. These accessories are engineered to withstand harsh pool environments and provide reliable operation. For more details, refer to the Hayward website or consult your local authorized dealer to find the right accessories for your specific needs.
Hayward Customer Support
For any inquiries or assistance with your Hayward Super Pump 700, contact Hayward’s dedicated customer support team. Reach them at (908) 355-7995 or visit their website at www.hayward.com. Hayward offers comprehensive resources, including troubleshooting guides, maintenance tips, and replacement part information. Their website also provides access to product manuals and registration services. For optimal performance, ensure to use only genuine Hayward parts. If you encounter issues, trained professionals are available to guide you through solutions. Register your product online to activate warranties and receive exclusive support benefits. Hayward’s commitment to customer satisfaction ensures reliable assistance for all your pool equipment needs.